Page 249 - 增刊2023年质量管理交流研讨会论文集(1)(1)
P. 249

2023 年质量管理经验交流论文汇编




                                   城镇供热管道保温技术质量管理要点

                                                      刘欢,唐晓兵
                           中国能源建设集团江苏省电力设计院有限公司,江苏省南京市,211102

                   摘要:城镇集中供热具有参数高,供热范围广等特点,其供热效率受多方面因素影响,
                   其中管道保温质量直接影响介质温度的控制,进而决定了供热管道温降等参数指标。
                   通过对某项目大管径供热管道保温设计要点进行分析,提出保温施工的重点及难点;
                   并对现场保温施工过程中容易出现的一些质量问题进行总结,提出了针对性的改进措
                   施,以便提高供热管道保温施工质量,确保蒸汽温降在合理范围内。经管道运行检验,
                   通过本文的质量管控措施,可将管道温降指标控制在设计值合理范围内。
                   关键词: 集中供热;保温施工;温降;质量控制

                                     Quality Management points of the

                                         thermal insulation technique
                                  for heating pipeline in cities and towns
                                                   LIU Huan, TANG Xiaobing
                           China Energy Engineering Group Jiangsu Power Design Institute Co., Ltd. Nanjing,
                                                      Jiangsu, 211102

                   Abstract: The heating efficiency of central heating with high parameters and wide heating range
                   characteristics  in  cities  is  affected  by  many  factors.  The  quality  of  pipe  insulation  directly
                   affects the control of medium temperature, and then determines the temperature reduction value
                   and  other  parameters  of  the  heating  pipeline.  The  paper  analysis  the  key  points  of  thermal
                   insulation design for large diameter heating pipeline, and put forward the major and difficult
                   points of thermal insulation construction. The paper summarizes some quality problems that are
                   easy to occur during insulation construction. It proposes some targeted improvement measures
                   for the target which is improve the construction quality of heating pipeline insulation and ensure
                   the  steam  temperature  reduction  value  within  a  reasonable  range.  After  pipeline  operation
                   inspection,  the  temperature  reduction  value  of  the  pipeline  can  be  controlled  within  the
                   reasonable range of the design value with the quality control measures in the paper.
                   Key  words:  Central  heating;  Thermal  insulation  construction;  Temperature  reduction  value;
                       Quality Control

                   1 引言
                       随着社会经济水平的提升,中国城镇规模也在不断扩大,为了节约能源,保护环境,
                   助力“3060” 碳达峰碳中和目标的实现,逐步关停区域小型锅炉、以大型热电厂作为热
                   源发展城镇集中供热已成为趋势。城镇集中供热项目大部分都地处热负荷中心,供热效率
                   高,可对地方能源综合利用,节能减排,促进生产,改善人民生活水平做出积极贡献。
                       但随着城镇地域范围的不断扩张,用热负荷较大的企业不断外迁,导致集中供热的范
                   围也在不断的扩大。供热蒸汽长距离输送会面临沿途热量损失等问题,因此需要根据沿管
                   道流向蒸汽温度降低(以下称“温降”)的目标值,设计一套可靠的管道保温系统,以减
                   少管道及其附属构件向周围环境散热,将温降控制在目标范围内。
                       本文结合某热电联产项目配套热网工程 EPC 工程总承包项目的具体情况,探讨分析大
                   管径供热蒸汽管道保温的设计要点及施工质量的管控措施。该项目为新建 DN800 供热蒸汽
                   管道,管道接入点蒸汽温度为 370℃,蒸汽压力为 2.5Mpa,工程全长约 20 公里,采用架
                   空敷设、顶管敷设、地埋敷设相结合,属于城镇供热蒸汽管道工程(GB2 类)。管道末端出
                   口蒸汽的温度等参数是本工程重要的技术控制指标,而长距离输送和复杂的管道路由,将





                                                                                                   244
   244   245   246   247   248   249   250   251   252   253   254